English 繁體中文

telephone: (886)-4-23354488
e-mail: [email protected]

Short-Arc Xeonon Lamps

  • Short-Arc Xenon Lamps (1000W~7500W)
  • Short-Arc Mercury Xenon Lamps (1000W~7500W)

Chao Li's technicians have passed several government-organized tests and certifications to ensure an emphasis on standard and precise operations and detailed testing.

Usage Recommendations - Short Arc Xenon Lamps

  • Average operating life: The average operating life represents the average number of hours a lamp can be in continuous use at its rated power. A lamp is at the end of its operating life when either of the following has occurred:
    • The horizontal luminous intensity or total flux has dropped to 70% of its initial value
    • The lamp no longer lights up
  • It is recommended that these lamps be powered by constant power supply
  • Do not touch the quartz surface of the bulb. When touched accidently, remove fingerprints or stains with an alcohol soaked cloth, otherwise they weaken the quartz surface and may cause an explosion.
  • Make sure the lamp/bulb is free from mechanical stress.
  • Lower Current: For the best results, we recommend using a lower current than the rated value. This will result in the bulb having a longer operating life.
  • Flicker: When flickering is observed, do the following:
    • Increase the current to the rated value. Operate the bulb for 1/2 hour. Decrease current to the normal operation setting.
    • Rotate the bulb 90-180 degrees.
  • Fix the bulb at one end only. It must be free to expand during operation so as to prevent mechanical failure.

Short Arc Mercury Xenon Lamps

Average operating life: The average operating life represents the average number of hours a lamp can be in continuous use at its rated power. A lamp is at the end of its operating life when either of the following has occurred:

  • The horizontal luminous intensity or total flux has dropped to 70% of its initial value
  • The lamp no longer lights up

Cooling conditions should be adjusted properly so that the base surface temperature is kept below 200 degrees centigrade and at the same time mercury is completely evaporated D1 does not include the height of the chip.

It is recommended that these lamps be powered by constant power supply.

 

Short Arc Mercury Xenon Lamps

  • Average operating life: The average operating life represents the average number of hours a lamp can be in continous use at its rated power. A lamp is at the end of its operating life when either of the following has occurred:

    • The horizontal luminous intensity or total flux has dropped to 70% of its initial value

    • The lamp no longer lights up

  • It is recommended that these lamps be powered by contant power supply

  • Do not touch the quarz surface of the bulb. When touched accidently, remove fingerprints or stains with an alcohol soaked cloth. Otherwise they weaken the quartz surface and may cause an explosion

  • Make sure the lamp/bulb is free from mechanical stress

  • Lower Current: With a lower current than the rated value, the bulb will operate for longer life. It is recommended that the best results are obtained at a lower current than the rated value

  • Flicker: When flickering is observed, do the following:

    • Increase the current to the rated value. Operate the bulb for 1/2 hour. Decrease current to the normal operation setting

    • Rotate the bulb 90-180 degrees

  • Free to expand: Fix the bulb at one end only. It must be free to expand during operation so as to prevent mechanical failure

Our Products Gallery

Gallery Image


Contact Chao Li

Chao Li Electrical Group
Tel: (886)-4-23354488
Fax:(886)-4-23354334

Address: No. 188,, Thai-Ming Road, Wu Ri
District, Taichung Country, Taichung, Taiwan

Click to view location map